PUMPSENSE FLUID ENGINEERING PVT LTD | ||||||
---|---|---|---|---|---|---|
QAP FOR PERFORMANCE TEST |
||||||
NPSHa in this condition - = { Atmospheric Pressure (m) + (suction gauge reading at that point (kgf/cm2) x 10) m + (Velocity Head at suction line of gauge connection)
m - (Level Difference Between Gauge Connection Point & Impeller C/L ) m – (Liquid Vapor Pressure at testing Temperature) m } |
||||||